SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
223
2 Parameters
2.2 List of parameters
Description: Setting to invert the signals at the digital outputs of Terminal Module 15 (TM15).
Note: DI/DO: Bidirectional Digital Input/Output
Description: Setting to invert the signals at the digital outputs of Terminal Module 31 (TM31).
Note: DO: Digital Output
DI/DO: Bidirectional Digital Input/Output
p4048 TM15DI/DO invert digital outputs / TM15D DO inv
TM15DI_DO Can be changed: U, T Calculated: - Access level: 1
Data type: Unsigned32 Dyn. index: - Func. diagram: 9400, 9401,
9402
P-Group: Commands Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0000 0000 0000 0000 0000
0000 0000 0000 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 DI/DO 0 (X520.2) Inverted Not inverted -
01 DI/DO 1 (X520.3) Inverted Not inverted -
02 DI/DO 2 (X520.4) Inverted Not inverted -
03 DI/DO 3 (X520.5) Inverted Not inverted -
04 DI/DO 4 (X520.6) Inverted Not inverted -
05 DI/DO 5 (X520.7) Inverted Not inverted -
06 DI/DO 6 (X520.8) Inverted Not inverted -
07 DI/DO 7 (X520.9) Inverted Not inverted -
08 DI/DO 8 (X521.2) Inverted Not inverted -
09 DI/DO 9 (X521.3) Inverted Not inverted -
10 DI/DO 10 (X521.4) Inverted Not inverted -
11 DI/DO 11 (X521.5) Inverted Not inverted -
12 DI/DO 12 (X521.6) Inverted Not inverted -
13 DI/DO 13 (X521.7) Inverted Not inverted -
14 DI/DO 14 (X521.8) Inverted Not inverted -
15 DI/DO 15 (X521.9) Inverted Not inverted -
16 DI/DO 16 (X522.2) Inverted Not inverted -
17 DI/DO 17 (X522.3) Inverted Not inverted -
18 DI/DO 18 (X522.4) Inverted Not inverted -
19 DI/DO 19 (X522.5) Inverted Not inverted -
20 DI/DO 20 (X522.6) Inverted Not inverted -
21 DI/DO 21 (X522.7) Inverted Not inverted -
22 DI/DO 22 (X522.8) Inverted Not inverted -
23 DI/DO 23 (X522.9) Inverted Not inverted -
p4048 TM31 invert digital outputs / TM31 DO inv
TM31 Can be changed: U, T Calculated: - Access level: 1
Data type: Unsigned32 Dyn. index: - Func. diagram: 9556, 9560,
9562
P-Group: Commands Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0000 0000 0000 0000 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 DO 0 (X542.1 - 3) Inverted Not inverted -
01 DO 1 (X542.4 - 6) Inverted Not inverted -
08 DI/DO 8 (X541.2) Inverted Not inverted -
09 DI/DO 9 (X541.3) Inverted Not inverted -
10 DI/DO 10 (X541.4) Inverted Not inverted -
11 DI/DO 11 (X541.5) Inverted Not inverted -