SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
481
2 Parameters
2.2 List of parameters
Dependency: Refer to: p50092, p50580, p50583, r53195
Description: Sets the signal source for the speed actual value when reversing the field.
Dependency: Refer to: p50092, p50580, p50581, r53195
Description: Sets the signal source for the speed setpoint for the "Setpoint/actual value deviation 1" message.
Dependency: Refer to: p50591, r53025
Refer to: F60031
Description: Sets the signal source for the speed actual value for the "Setpoint/actual value deviation 1" message.
Dependency: Refer to: p50590, r53025
Refer to: F60031
Description: Sets the signal source for the speed actual value for the "Reference speed reached" message.
Dependency: Refer to: r53025
p50583[0...n] CI: Field reversal speed actual value signal source / FldRev n_act sig s
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / FloatingPoint32 Dyn. index: CDS, p0170 Func. diagram: 6920
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 52167[0]
p50590 CI: Messages for set/act val dev 1 signal source for speed setpoint /
Msg dev1 set sig s
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / FloatingPoint32 Dyn. index: - Func. diagram: 8020
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 52165[0]
p50591 CI: Messages for set/act val dev 1 signal source for speed act val / Msg dev1 act sig s
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / FloatingPoint32 Dyn. index: - Func. diagram: 8020
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 0
p50592 CI: Messages for ref speed signal source for speed actual value / Msg ref act sig s
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / FloatingPoint32 Dyn. index: - Func. diagram: 8020
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 52167[0]