2 Parameters
2.2 List of parameters
SINAMICS DCM
490 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Sets the signal source for band-stop 1.
Dependency: Refer to: p50201, p50202, r52177
Description: Sets the signal source for band-stop 2.
Dependency: Refer to: p50203, p50204, r52178
Description: Sets the signal source for the droop on the speed controller.
Description: Sets the signal source for the setting value of the integral component for the speed controller.
Dependency: Refer to: p50230, p50695
Description: Sets the signal sources for positive limiting after the ramp-function generator (setpoint limiting).
Note: The minimum of the signals is forwarded to the limiter via connector input p50632[0 to 3].
p50628 CI: Band-stop 1 signal source / Band-st 1 sig s
DC_CTRL Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dyn. index: - Func. diagram: 6810
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 52179[0]
p50629 CI: Band-stop 2 signal source / Band-st 2 sig s
DC_CTRL Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dyn. index: - Func. diagram: 6810
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 52177[0]
p50630 CI: Speed controller droop signal source / Droop sig s
DC_CTRL Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dyn. index: - Func. diagram: 6805
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 52162[0]
p50631 CI: Speed controller integral component setting value signal source / I_co set v sig s
DC_CTRL Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dyn. index: - Func. diagram: 6815
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 0
p50632[0...3] CI: RFG signal source for positive limiting after RFG / RFG pos lim sig s
DC_CTRL Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dyn. index: - Func. diagram: 3155
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 1