2 Parameters
2.2 List of parameters
SINAMICS DCM
46 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: The parameter contains the object number via which every drive object can be addressed.
The number of an existing drive object is entered into each index.
Value = 0: No drive object is defined.
Note: The numbers are automatically allocated.
For the commissioning software, this object number cannot be entered using the expert list, but is automatically
assigned when inserting an object.
Description: Displays the number of existing or existing and prepared drive objects.
Index: [0] = Existing drive objects
[1] = Existing and prepared drive objects
Dependency: Refer to: p0101
Note: The numbers of the drive objects are in p0101.
Index 0:
Displays the number of drive objects that have already been set up.
Index 1:
Displays the number of drive objects that have already been set up and, in addition, the drive objects that still have to
be set up.
Description: The application-specific view of an existing drive object is entered into each index.
The parameter cannot be changed.
Dependency: Refer to: p0107, r0107
Note: The application-specific views are defined in files on the memory card with the following structure:
PDxxxyyy.ACX
xxx: Application-specific view (p0103)
yyy: Type of drive object (p0107)
Example:
PD052017.ACX
--> "017" stands for the drive object of type DC_CTRL
--> "052" is the number of the view for this drive object
p0101[0...n] Drive object numbers / DO numbers
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: C1(1) Calculated: - Access level: 2
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: Topology Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 62 0
r0102[0...1] Number of drive objects / DO count
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: - Calculated: - Access level: 2
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: Topology Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
p0103[0...n] Application-specific view / Appl_spec view
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: C1(2) Calculated: - Access level: 2
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 999 0