2 Parameters
2.2 List of parameters
SINAMICS DCM
538 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Sets the signal source for changing over the setpoint between positive and negative start pulses on the speed
controller.
Description: Sets the signal source for travel command 1 on the 4-step master switch.
Description: Sets the signal source for travel command 2 on the 4-step master switch.
Description: Sets the signal source for changing over to setpoint step S2 on the 4-step master switch.
Description: Sets the signal source for changing over to setpoint step S3 on the 4-step master switch.
p51657[0...n] BI: Speed controller start pulse pos/neg changeover signal source / Start p ch sig s
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dyn. index: CDS, p0170 Func. diagram: 6800
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0
p51660 BI: Signal source for master switch travel command 1 / Trav comm 1 sig s
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dyn. index: - Func. diagram: 3105
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0
p51661 BI: Signal source for master switch travel command 2 / Trav comm 2 sig s
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dyn. index: - Func. diagram: 3105
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0
p51662 BI: Signal source for master switch setpoint step S2 / Set step S2 sig s
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dyn. index: - Func. diagram: 3105
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0
p51663 BI: Signal source for master switch setpoint step S3 / Set step S3 sig s
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dyn. index: - Func. diagram: 3105
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0

Table of Contents

Other manuals for Siemens SINAMICS DCM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS DCM and is the answer not in the manual?

Siemens SINAMICS DCM Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS DCM
CategoryMedia Converter
LanguageEnglish

Related product manuals