SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
463
2 Parameters
2.2 List of parameters
Description: Sets the minimum speed on the motorized potentiometer.
Dependency: Refer to: p50471
Note: This parameter is only effective in manual mode (p50471 = 0).
The setpoint output from the motorized potentiometer is limited to this value.
Description: Sets the signal source for changing over between clockwise/counter-clockwise rotation on the motorized
potentiometer.
Description: Sets the signal source for changing between manual and automatic modes.
Dependency: Refer to: p50461, p50673, p50674
Note: If p50471 = 0 signal (manual mode):
In manual mode, the setpoint is increased and reduced using binector inputs p50673 and p50674 respectively.
If p50471 = 1 signal (automatic mode):
In automatic mode, the setpoint is specified using connector input p50461.
Description: Sets the signal source to accept the setting value for the motorized potentiometer.
Dependency: Refer to: p50466
Note: The setting value (CI: p50466) becomes effective on a 0/1 edge of the setting command (BI: p50472).
p50469[0...n] Motorized potentiometer minimum speed / MotP n_min
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 3110
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
-200.00 [%] 200.00 [%] -100.00 [%]
p50470[0...n] BI: Motorized potentiometer signal source for CW/CCW / MotP CW/CCW sig s
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dyn. index: CDS, p0170 Func. diagram: 3110
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0
p50471[0...n] BI: Motorized potentiometer signal source for manual/automatic / MotP man/aut sig s
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dyn. index: CDS, p0170 Func. diagram: 3110
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0
p50472[0...n] BI: Motorized potentiometer accept setting value / MotP acc set val
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dyn. index: CDS, p0170 Func. diagram: 3110
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0