EasyManuals Logo

Siemens SINAMICS DCM List Manual

Siemens SINAMICS DCM
1204 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #478 background imageLoading...
Page #478 background image
2 Parameters
2.2 List of parameters
SINAMICS DCM
478 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Sets the amplitude for the frequency response plot for the optimization run "Speed control optimization for drives that
are capable of oscillation" (p50051 = 29).
Description: Sets the time for the frequency response plot for the optimization run "Speed control optimization for drives that are
capable of oscillation" (p50051 = 29).
In this case, an average is generated over the time set here per measuring frequency.
Note: High values improve the result, however they slow down the measuring time.
For the 3.0 s setting, it takes approximately 9 minutes to plot the frequency response.
Description: Sets the input quantity for armature current controller adaptation.
Value: 0: Ia_act r52117
1: Ia_set r52119
Dependency: Refer to: p50571, p50572
Description: Setting to activate the adaptation of non-linear inductances for the armature current controller.
Value: 0: Adaptation non-linear L active
1: Fixed value 100 % effective
Dependency: Refer to: p50570, p50572, r52350
p50566 Speed controller optimization frequency response plot amplitude / f_plot amplitude
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 2660
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
0.01 [%] 5.00 [%] 1.00 [%]
p50567 Speed controller optimization frequency response plot time / f_plot time
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 2660
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.30 [s] 3.00 [s] 1.00 [s]
p50570[0...n] Adaptation armature current controller changeover input / Adapt Ia chgov inp
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: Integer16 Dyn. index: DDS, p0180 Func. diagram: 6853
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1 0
p50571[0...n] Adaptation armature current controller non-linear L activation / Adapt N_lin L act
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: Integer16 Dyn. index: DDS, p0180 Func. diagram: 6853
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1 0

Table of Contents

Other manuals for Siemens SINAMICS DCM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS DCM and is the answer not in the manual?

Siemens SINAMICS DCM Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS DCM
CategoryMedia Converter
LanguageEnglish

Related product manuals