2 Parameters
2.2 List of parameters
SINAMICS DCM
642 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Display and connector output/binector output for the state of the fuses at X23C.
The fuses are monitored via connection A7112:X23C.
Dependency: Refer to: p51831
Refer to: F60204
Note: The fuses are only set to "OK" in operating state o7.0. The fuses are set to "ruptured" in all other operating states.
The parameter is only relevant for the Control Module.
Description: Display and connector output/binector output for the state of the fuses at X23D.
The fuses are monitored via connection A7112:X23D.
Dependency: Refer to: p51831
Refer to: F60204
Note: The fuses are only set to "OK" in operating state o7.0. The fuses are set to "ruptured" in all other operating states.
The parameter is only relevant for the Control Module.
Description: Display and connector output/binector output for the state of the fuses at X23E.
The fuses are monitored via connection A7112:X23E.
r53221.0...5 CO/BO: Fuses at X23C state / Fuses X23C
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: Unsigned16 Dyn. index: - Func. diagram: 6957
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Fuse XS1 Okay Ruptured -
01 Fuse XS2 Okay Ruptured -
02 Fuse XS3 Okay Ruptured -
03 Fuse XS4 Okay Ruptured -
04 Fuse XS5 Okay Ruptured -
05 Fuse XS6 Okay Ruptured -
r53222.0...5 CO/BO: Fuses at X23D state / Fuses X23D
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: Unsigned16 Dyn. index: - Func. diagram: 6957
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Fuse XS1 Okay Ruptured -
01 Fuse XS2 Okay Ruptured -
02 Fuse XS3 Okay Ruptured -
03 Fuse XS4 Okay Ruptured -
04 Fuse XS5 Okay Ruptured -
05 Fuse XS6 Okay Ruptured -
r53223.0...5 CO/BO: Fuses at X23E state / Fuses X23E
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: Unsigned16 Dyn. index: - Func. diagram: 6957
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -