2 Parameters
2.2 List of parameters
Description: Sets the delay time for digital input/output 4 (X177.15) on the CUD.
Dependency: The terminal must be set as an output (p50789[0] = 1).
Refer to: p50789
Note: The level at the digital output can only change if the changed internal level remains constant for longer than the set
delay time.
Description: Sets the delay time for digital input/output 5 (X177.16) on the CUD.
Dependency: The terminal must be set as an output (p50789[1] = 1).
Refer to: p50789
Note: The level at the digital output can only change if the changed internal level remains constant for longer than the set
delay time.
Description: Sets the delay time for digital input/output 6 (X177.17) on the CUD.
Dependency: The terminal must be set as an output (p50789[2] = 1).
Refer to: p50789
Note: The level at the digital output can only change if the changed internal level remains constant for longer than the set
delay time.
Description: Sets the delay time for digital input/output 7 (X177.18) on the CUD.
Dependency: The terminal must be set as an output (p50789[3] = 1).
Refer to: p50789
Note: The level at the digital output can only change if the changed internal level remains constant for longer than the set
delay time.
p50785 CUD digital input/output 4 delay time / CUD DI/DO 4 t_del
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 2060
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 [ms] 10000 [ms] 0 [ms]
p50786 CUD digital input/output 5 delay time / CUD DI/DO 5 t_del
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 2060
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 [ms] 10000 [ms] 0 [ms]
p50787 CUD digital input/output 6 delay time / CUD DI/DO 6 t_del
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 2065
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 [ms] 10000 [ms] 0 [ms]
p50788 CUD digital input/output 7 delay time / CUD DI/DO 7 t_del
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 2065
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 [ms] 10000 [ms] 0 [ms]