2 Parameters
2.2 List of parameters
SINAMICS DCM
388 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Displays the serial number of the power unit.
Note: The individual digits of the number are displayed in ASCII code in the indices.
An ASCII table (excerpt) can be found, for example, in the appendix to the List Manual.
Description: Displays the order number (MLFB) of the power unit.
Note: The individual digits of the number are displayed in ASCII code in the indices.
An ASCII table (excerpt) can be found, for example, in the appendix to the List Manual.
Description: Displays the device rated line-side voltage for the armature as indicated on the device's nameplate.
Description: Displays the device rated direct current (armature).
Index: [0] = Device rated direct current armature
[1] = Reduced rated direct current armature
Note: Re index 0:
Device rated direct current (armature) as indicated on the device's nameplate.
Re index 1:
Actual device rated direct current (armature) according to the setting in parameter p50076[0] or p50067.
Also see the note for parameter p50076[0].
r50069[0...31] Power unit serial number / PU ser no.
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: Unsigned8 Dyn. index: - Func. diagram: 6960
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r50070[0...31] Power unit order number / PU Order No.
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: Unsigned8 Dyn. index: - Func. diagram: 6960
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r50071 Device rated line-side voltage armature / Device Ua_rated
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6960
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [Vrms] - [Vrms] - [Vrms]
r50072[0...1] Device rated direct current armature / Device Ia rated
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6800, 6825,
6830, 6840, 6850, 6851, 6855,
6910, 6960, 6965, 8038, 8040,
8042
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [A] - [A] - [A]