Siemens SINAMICS DCM - BI: TM15 DI;DO Signal Source for Terminal DI;DO 20; TM15 D S_Srcdi;Do20; BI: TM15 DI;DO Signal Source for Terminal DI;DO 21; TM15 D S_Srcdi;Do21; BI: TM15 DI;DO Signal Source for Terminal DI;DO 22; TM15 D S_Srcdi;Do22; BI: TM15 DI;DO Signal Source for Terminal DI;DO 23; TM15 D S_Srcdi;Do23

Siemens SINAMICS DCM
1204 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
233
2 Parameters
2.2 List of parameters
Description: Sets the signal source for terminal DI/DO 20 (X522.6) of Terminal Module 15 (TM15).
Note: Prerequisite: The DI/DO must be set as an output (p4028.20 = 1).
DI/DO: Bidirectional Digital Input/Output
Description: Sets the signal source for terminal DI/DO 21 (X522.7) of Terminal Module 15 (TM15).
Note: Prerequisite: The DI/DO must be set as an output (p4028.21 = 1).
DI/DO: Bidirectional Digital Input/Output
Description: Sets the signal source for terminal DI/DO 22 (X522.8) of Terminal Module 15 (TM15).
Note: Prerequisite: The DI/DO must be set as an output (p4028.22 = 1).
DI/DO: Bidirectional Digital Input/Output
Description: Sets the signal source for terminal DI/DO 23 (X522.9) of Terminal Module 15 (TM15).
Note: Prerequisite: The DI/DO must be set as an output (p4028.23 = 1).
DI/DO: Bidirectional Digital Input/Output
p4090 BI: TM15DI/DO signal source for terminal DI/DO 20 / TM15D s_srcDI/DO20
TM15DI_DO Can be changed: U, T Calculated: - Access level: 1
Data type: Unsigned32 / Binary Dyn. index: - Func. diagram: 9402
P-Group: Commands Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0
p4091 BI: TM15DI/DO signal source for terminal DI/DO 21 / TM15D s_srcDI/DO21
TM15DI_DO Can be changed: U, T Calculated: - Access level: 1
Data type: Unsigned32 / Binary Dyn. index: - Func. diagram: 9402
P-Group: Commands Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0
p4092 BI: TM15DI/DO signal source for terminal DI/DO 22 / TM15D s_srcDI/DO22
TM15DI_DO Can be changed: U, T Calculated: - Access level: 1
Data type: Unsigned32 / Binary Dyn. index: - Func. diagram: 9402
P-Group: Commands Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0
p4093 BI: TM15DI/DO signal source for terminal DI/DO 23 / TM15D s_srcDI/DO23
TM15DI_DO Can be changed: U, T Calculated: - Access level: 1
Data type: Unsigned32 / Binary Dyn. index: - Func. diagram: 9402
P-Group: Commands Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0