2 Parameters
2.2 List of parameters
SINAMICS DCM
568 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Display and connector output of the signed armature current actual value.
The value is averaged over 6 firing cycles.
Description: Display and connector output for the closed-loop armature current control output.
Description: Display and connector output for the proportional component of closed-loop armature current control.
Description: Display and connector output for the integral component of closed-loop armature current control.
Description: Display and connector output for the setpoint/actual value difference of closed-loop armature current control.
r52109 CO: Armature current actual value averaged over 6 cycles / Ia act 6 cyc
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6851, 6902,
8038, 8042, 8046
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52110 CO: Cl-loop arm curr control curr controller output / Ia ctr outp
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6855
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52111 CO: Cl-loop arm curr control curr controller outp proportional comp /
Ia ctr outp P comp
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6855
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52112 CO: Cl-loop arm curr control curr controller outp integral comp / Ia ctr outp I comp
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6855
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52113 CO: Cl-loop arm curr control curr setpoint/actual value difference / Ia ctr set/act
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6855
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]