SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
573
2 Parameters
2.2 List of parameters
Description: Display and connector output for the current controller setpoint before current limitation.
Description: Display and connector output for the variable torque limiting defaults in torque direction II.
Dependency: Refer to: p50603, p50604
Note: Connector output r52135[0 to 6] is the inverse of p50603[0 to 6] and interconnected by default via connector input
p50604[0 to 6].
Description: Display and connector output for the effective upper torque limit (maximum value) on the speed limiting controller.
Dependency: Refer to: r52137
Description: Display and connector output for the effective lower torque limit (minimum value) on the speed limiting controller.
Dependency: Refer to: r52136
Description: Display and connector output for the defaults for variable negative torque limiting.
Dependency: Refer to: p50606
Note: Connector output r52138[0 to 4] is the inverse of p50605[0 to 4]; it is interconnected by default via connector input
p50606[0 to 4].
r52134 CO: Speed limiting controller curr controller setp before limitation / Ia set bef lim
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6835
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52135[0...6] CO: Current limitation default for torque direction II / Ia lim def t d II
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6840
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52136 CO: Speed limiting controller upper torque limit effective / n_lim t lim up max
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6835
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52137 CO: Speed limiting controller lower torque limit effective / n_lim t lim l min
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6835
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52138[0...4] CO: Torque limiting negative default / Tqe lim neg def
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6825
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]