EasyManua.ls Logo

Siemens SINAMICS DCM - CO: Current Limitation Default for Torque Direction II; CO: Speed Limiting Controller Curr Controller Setp before Limitation; CO: Speed Limiting Controller Lower Torque Limit Effective; CO: Speed Limiting Controller Upper Torque Limit Effective

Siemens SINAMICS DCM
1204 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
573
2 Parameters
2.2 List of parameters
Description: Display and connector output for the current controller setpoint before current limitation.
Description: Display and connector output for the variable torque limiting defaults in torque direction II.
Dependency: Refer to: p50603, p50604
Note: Connector output r52135[0 to 6] is the inverse of p50603[0 to 6] and interconnected by default via connector input
p50604[0 to 6].
Description: Display and connector output for the effective upper torque limit (maximum value) on the speed limiting controller.
Dependency: Refer to: r52137
Description: Display and connector output for the effective lower torque limit (minimum value) on the speed limiting controller.
Dependency: Refer to: r52136
Description: Display and connector output for the defaults for variable negative torque limiting.
Dependency: Refer to: p50606
Note: Connector output r52138[0 to 4] is the inverse of p50605[0 to 4]; it is interconnected by default via connector input
p50606[0 to 4].
r52134 CO: Speed limiting controller curr controller setp before limitation / Ia set bef lim
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6835
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52135[0...6] CO: Current limitation default for torque direction II / Ia lim def t d II
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6840
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52136 CO: Speed limiting controller upper torque limit effective / n_lim t lim up max
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6835
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52137 CO: Speed limiting controller lower torque limit effective / n_lim t lim l min
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6835
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52138[0...4] CO: Torque limiting negative default / Tqe lim neg def
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6825
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]

Table of Contents