SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
601
2 Parameters
2.2 List of parameters
Description: Display and connector output for the negative setpoint of the start pulse on the speed controller.
Description: Display and connector output for the output value of the start pulse on the speed controller.
Description: Display and connector output for the setpoint prevailing on the 4-step master switch.
Description: Display and connector output for word 1 of the receive data on the peer-to-peer interface (P2P IF).
Dependency: Refer to: r52606
Description: Display and connector output for word 2 of the receive data on the peer-to-peer interface (P2P IF).
Dependency: Refer to: r52607
r52453 CO: Speed controller start pulse negative setpoint / Start pul neg set
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6800
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52454 CO: Speed controller start pulse output value / Start pul outp val
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6800
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52510 CO: Master switch setpoint output / Set outp
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 3105
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52601 CO: P2P IF receive data word 1 / P2P recv 1
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 9300
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52602 CO: P2P IF receive data word 2 / P2P recv 2
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 9300
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]