2 Parameters
2.2 List of parameters
SINAMICS DCM
482 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Sets the signal source for the "Speed less then minimum speed" message.
Dependency: Refer to: r53025
Description: Sets the signal source for the "Speed setpoint polarity" message.
Dependency: Refer to: p50372, r53025
Description: Sets the signal source for the speed actual value for the overspeed message.
Dependency: Refer to: p50380, p50381, r53025
Refer to: F60038
Description: Sets the signal source for the speed setpoint for the "Setpoint/actual value deviation 2" message.
Dependency: Refer to: p50597, r53025
Description: Sets the signal source for the speed actual value for the "Setpoint/actual value deviation 2" message.
p50593 CI: Messages for speed less than min speed signal source for act val /
Msg n<n_min sig s
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / FloatingPoint32 Dyn. index: - Func. diagram: 8020
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 52167[0]
p50594[0...n] CI: Messages polarity speed setpoint signal source / MsgPol n_set S_src
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / FloatingPoint32 Dyn. index: CDS, p0170 Func. diagram: 8025
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 52170[0]
p50595 CI: Signal source for overspeed messages / Msg n_over sig s
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / FloatingPoint32 Dyn. index: - Func. diagram: 8025
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 52167[0]
p50596 CI: Messages for set/act val dev 2 signal source for speed setpoint /
Msg dev2 set sig s
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / FloatingPoint32 Dyn. index: - Func. diagram: 8020
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 52174[0]
p50597 CI: Messages for set/act val dev 2 signal source for speed act val / Msg dev2 act sig s
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / FloatingPoint32 Dyn. index: - Func. diagram: 8020
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 52167[0]