2 Parameters
2.2 List of parameters
SINAMICS DCM
514 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Setting to invert the signals at the CUD's digital outputs.
Value: 0: Not inverted
1: Inverted
Index: [0] = DO 0 (X177.19)
[1] = DO 1 (X177.20)
[2] = DO 2 (X177.21)
[3] = DO 3 (X177.22)
Note: DO: Digital Output
Description: Sets the signal source for digital output 0 (X177.19) on the CUD.
Description: Sets the signal source for digital output 1 (X177.20) on the CUD.
Description: Sets the signal source for digital output 2 (X177.21) on the CUD.
Description: Sets the signal source for digital output 3 (X177.22) on the CUD.
Note: A restart is required if p50774 is logically combined with (2)r51579.0!
p50770[0...3] CUD digital outputs inversion / CUD DO inv
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: Integer16 Dyn. index: - Func. diagram: 2055
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1 0
p50771 BI: CUD digital output 0 signal source / CUD DO 0 sig s
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dyn. index: - Func. diagram: 2055
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0
p50772 BI: CUD digital output 1 signal source / CUD DO 1 sig s
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dyn. index: - Func. diagram: 2055
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0
p50773 BI: CUD digital output 2 signal source / CUD DO 2 sig s
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dyn. index: - Func. diagram: 2055
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0
p50774 BI: CUD digital output 3 signal source / CUD DO 3 sig s
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dyn. index: - Func. diagram: 2055
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0