2 Parameters
2.2 List of parameters
Description: Displays the transmit data for the peer-to-peer interface (P2P IF).
The signal source for the data to be transmitted is set via connector input p50794[0 to 4].
Index: [0] = Word 1
[1] = Word 2
[2] = Word 3
[3] = Word 4
[4] = Word 5
Dependency: Refer to: p50794
Description: Sets the signal source to enable data to be received on the peer-to-peer interface (P2P IF).
1 signal: Data receive enabled
0 signal: Data receive not enabled
Description: Sets the signal source to enable data to be transmitted on the peer-to-peer interface (P2P IF).
1 signal: Data transmission enabled
0 signal: Data transmission not enabled
Description: Sets the bus terminator for the RS485 interface (PPI/USS, X178).
Value: 0: OFF
1: ON
r50813[0...4] P2P IF transmit data display / P2P tr data disp
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: Unsigned16 Dyn. index: - Func. diagram: 9300
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
p50816 BI: P2P IF receive enable signal source / P2P recv ena sig s
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dyn. index: - Func. diagram: 9300
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 1
p50817 BI: P2P IF transmit enable signal source / P2P tr ena sig s
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dyn. index: - Func. diagram: 9300
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 1
p50820 PPI/USS bus terminator / PPI/USS bus term
DC_CTRL Can be changed: U, T Calculated: - Access level: 1
Data type: Integer16 Dyn. index: - Func. diagram: 2410
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1 1

Table of Contents

Other manuals for Siemens SINAMICS DCM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS DCM and is the answer not in the manual?

Siemens SINAMICS DCM Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS DCM
CategoryMedia Converter
LanguageEnglish

Related product manuals