2 Parameters
2.2 List of parameters
SINAMICS DCM
406 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Setting of the field current for a motor flux of 40 %.
Note: This parameter is set automatically during the optimization run for field weakening (p50051 = 27).
Only values greater than p50127 and less than p50129 can be set.
Description: Setting of the field current for a motor flux of 45 %.
Note: This parameter is set automatically during the optimization run for field weakening (p50051 = 27).
Only values greater than p50128 and less than p50130 can be set.
Description: Setting of the field current for a motor flux of 50 %.
Note: This parameter is set automatically during the optimization run for field weakening (p50051 = 27).
Only values greater than p50129 and less than p50131 can be set.
Description: Setting of the field current for a motor flux of 55 %.
Note: This parameter is set automatically during the optimization run for field weakening (p50051 = 27).
Only values greater than p50130 and less than p50132 can be set.
p50128[0...n] Field current for motor flux 40 % / I_field flux 40%
DC_CTRL Can be changed: T Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 6900, 6910
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
0.0 [%] 100.0 [%] 29.4 [%]
p50129[0...n] Field current for motor flux 45 % / I_field flux 45%
DC_CTRL Can be changed: T Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 6900, 6910
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
0.0 [%] 100.0 [%] 33.1 [%]
p50130[0...n] Field current for motor flux 50 % / I_field flux 50%
DC_CTRL Can be changed: T Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 6900, 6910
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
0.0 [%] 100.0 [%] 36.8 [%]
p50131[0...n] Field current for motor flux 55 % / I_field flux 55%
DC_CTRL Can be changed: T Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 6900, 6910
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
0.0 [%] 100.0 [%] 40.6 [%]