2 Parameters
2.2 List of parameters
SINAMICS DCM
200 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Displays the last synchronizing event in the drive system.
3107[0, 1]: synchronizing event after synchronization
r3107[0]: milliseconds
r3107[1]: days
3107[2, 3]: synchronizing event before synchronization
r3107[2]: milliseconds
r3107[3]: days
Description: Displays the absolute value of the last synchronization deviation that was determined.
r3108[0]: Milliseconds
r3108[1]: Days
Description: Sets the tolerance window for time synchronization.
When this tolerance window is exceeded, an appropriate alarm is output.
Description: Sets the delay time for external fault 3.
Dependency: Refer to: p2108, p3111, p3112
r3107[0...3] RTC synchronizing time / RTC t_sync
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r3108[0...1] RTC last synchronization deviation / RTC sync_dev
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
p3109 RTC real time synchronization tolerance window / RTC sync tol
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 [ms] 1000 [ms] 100 [ms]
p3110 External fault 3 power-up delay / Ext fault 3 t_on
All objects Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned16 Dyn. index: - Func. diagram: 2546
P-Group: Messages Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 [ms] 1000 [ms] 0 [ms]