2 Parameters
2.2 List of parameters
Description: Display and connector output for the raw value at analog input 4 (X177.3/4) on the CUD.
Dependency: Refer to: r52021
Description: Display and connector output for the conversion result at analog input 4 (X177.3/4) on the CUD.
Description: Display and connector output for the raw value at analog input 5 (X177.5/6) on the CUD.
Dependency: Refer to: r52023
Description: Display and connector output for the conversion result at analog input 5 (X177.5/6) on the CUD.
Description: Display and connector output for the raw value at analog input 6 (X177.7/8) on the CUD.
Dependency: Refer to: r52025
r52020 CO: CUD analog input 4 raw value / CUD AI 4 raw
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 2085
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52021 CO: CUD analog input 4 result / CUD AI 4 res
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 2085
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52022 CO: CUD analog input 5 raw value / CUD AI 5 raw
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 2090
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52023 CO: CUD analog input 5 result / CUD AI 5 res
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 2090
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52024 CO: CUD analog input 6 raw value / CUD AI 6 raw
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 2090
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]