2 Parameters
2.2 List of parameters
SINAMICS DCM
272 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Sets the physical address for the second signal to be traced.
The data type is defined using p4731.
Index: [0] = Trace 0
[1] = Trace 1
Description: Sets the physical address for the third signal to be traced.
The data type is defined using p4732.
Index: [0] = Trace 0
[1] = Trace 1
Description: Sets the physical address for the fourth signal to be traced.
The data type is defined using p4733.
Index: [0] = Trace 0
[1] = Trace 1
Description: Sets the physical address for the fifth signal to be traced.
The data type is defined using p4734.
Index: [0] = Trace 0
[1] = Trace 1
p4781[0...1] Trace physical address signal 1 / Trace PhyAddr Sig1
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Trace and function generator Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
0000 bin 1111 1111 1111 1111 1111 1111
1111 1111 bin
0000 bin
p4782[0...1] Trace physical address signal 2 / Trace PhyAddr Sig2
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Trace and function generator Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
0000 bin 1111 1111 1111 1111 1111 1111
1111 1111 bin
0000 bin
p4783[0...1] Trace physical address signal 3 / Trace PhyAddr Sig3
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Trace and function generator Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
0000 bin 1111 1111 1111 1111 1111 1111
1111 1111 bin
0000 bin
p4784[0...1] Trace physical address signal 4 / Trace PhyAddr Sig4
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Trace and function generator Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
0000 bin 1111 1111 1111 1111 1111 1111
1111 1111 bin
0000 bin