2 Parameters
2.2 List of parameters
Description: Display and connector output for the sum "main setpoint (limited) + additional setpoint" before setpoint reduction.
Dependency: Refer to: p51607, p51608, r52194
Note: Setpoint reduction is set via p51608 and activated/de-activated via binector input p51607.
Description: Display and connector output for the effective upper limit in the case of main setpoint limiting.
Description: Display and connector output for the effective lower limit in the case of main setpoint limiting.
Description: Display and connector output for the main setpoint before setpoint limiting.
Description: Display and connector output for the sum of all creep setpoints (p504441[0 to 7]).
Dependency: Refer to: p50440, p50441
r52195 CO: Setpoint processing setpoint before reduction / Set before reduc
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 3135
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52196 CO: Setpoint processing main setpoint upper limit effective / M set up lim eff
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 3135
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52197 CO: Setpoint processing main setpoint lower limit effective / M set low lim eff
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 3135
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52198 CO: Setpoint processing main setpoint before limiting / M_setp bef lim
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 3135
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52201 CO: Creep setpoint output / Creep set outp
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 3130
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]