2 Parameters
2.2 List of parameters
SINAMICS DCM
380 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Displays the phase-to-phase line voltage in the armature circuit (rms value).
Description: Displays the line voltage in the field circuit (rms value).
Description: Displays the line frequency in the armature circuit/field circuit.
Index: [0] = Armature circuit
[1] = Field circuit
Description: Displays the firing angle on the armature circuit.
Description: Displays the internal signed current actual value in the armature circuit.
The value is averaged over 6 cycles.
Note: This parameter is referred to the rated motor current.
The following applies: 100% corresponds to p50100[ii], whereby ii = active DDS
r50015 Armature circuit rms value of phase-to-phase line voltage / Arm cct V_line rms
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6950
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [Vrms] - [Vrms] - [Vrms]
r50016 Field circuit line voltage rms value / F cct V_line rms
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6952
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [Vrms] - [Vrms] - [Vrms]
r50017[0...1] Line frequency / f_line
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6854, 6950,
6952
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [Hz] - [Hz] - [Hz]
r50018 Armature firing angle / Arm fir angle
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6860
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [°] - [°] - [°]
r50019 Armature current actual value / Arm I_act
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6850
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]