EasyManua.ls Logo

Siemens SINAMICS DCM - BI: Parallel Interface Signal Source for F60014; P if F60014 Sig S; Parallel Interface Activity Display; Par if Act Disp; Parallel Interface Diagnostic Information; Par if Diag Info

Siemens SINAMICS DCM
1204 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 Parameters
2.2 List of parameters
SINAMICS DCM
548 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Sets the signal source for triggering fault F60014 "Telegram monitoring timeout".
The fault is triggered on a 1 signal.
Dependency: Refer to: r53310
Refer to: F60014
Description: Displays the diagnostic information for the parallel interface.
Index: [0] = Telegrams transmitted without errors
[1] = Telegrams received without errors
[2] = Transmission error
[3] = Receive error
[4] = Timeouts
Dependency: Refer to: p51807
Note: The counters are reset to 0 at POWER ON.
The counters restart at 0 after reaching a value of 65535.
Description: Displays the activities on the individual stations on the parallel interface.
p51808 BI: Parallel interface signal source for F60014 / P IF F60014 sig s
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dyn. index: - Func. diagram: 9350
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 53310.0
r51809[0...4] Parallel interface diagnostic information / Par IF diag info
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: Unsigned16 Dyn. index: - Func. diagram: 9350
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r51810 Parallel interface activity display / Par IF act disp
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: Unsigned16 Dyn. index: - Func. diagram: 9350
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Station 1 transmitting data Yes No -
01 Station 2 transmitting data Yes No -
02 Station 3 transmitting data Yes No -
03 Station 4 transmitting data Yes No -
04 Station 5 transmitting data Yes No -
05 Station 6 transmitting data Yes No -
06 Station 7 transmitting data Yes No -
07 Station 8 transmitting data Yes No -
08 Station 9 transmitting data Yes No -
09 Station 10 transmitting data Yes No -
10 Station 11 transmitting data Yes No -
11 Station 12 transmitting data Yes No -
12 Station 13 transmitting data Yes No -
13 Station 14 transmitting data Yes No -
14 Station 15 transmitting data Yes No -
15 Station 16 transmitting data Yes No -

Table of Contents