2 Parameters
2.2 List of parameters
SINAMICS DCM
418 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Sets positive torque limit 1.
Dependency: Refer to: p50182
Note: If torque limit changeover is selected (p50694 = 1) and the speed is higher than the set changeover speed (p50184),
then torque limit 2 is activated in place of torque limit 1.
Description: Sets negative torque limit 1.
Dependency: Refer to: p50183
Note: If torque limit changeover is selected (p50694 = 1) and the speed is higher than the set changeover speed (p50184),
then torque limit 2 is activated in place of torque limit 1.
Description: Sets positive torque limit 2.
Dependency: Refer to: p50180
Note: If torque limit changeover is selected (p50694 = 1) and the speed is higher than the set changeover speed (p50184),
then torque limit 2 is activated in place of torque limit 1.
Description: Sets negative torque limit 2.
Dependency: Refer to: p50181
Note: If torque limit changeover is selected (p50694 = 1) and the speed is higher than the set changeover speed (p50184),
then torque limit 2 is activated in place of torque limit 1.
p50180[0...n] Torque limiting torque limit 1 positive / T lim 1 pos
DC_CTRL Can be changed: C2(1), U, T Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 6825
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
-300.00 [%] 300.00 [%] 300.00 [%]
p50181[0...n] Torque limiting torque limit 1 negative / T lim 1 neg
DC_CTRL Can be changed: C2(1), U, T Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 6825
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
-300.00 [%] 300.00 [%] -300.00 [%]
p50182[0...n] Torque limiting torque limit 2 positive / T lim 2 pos
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 6825
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
-300.00 [%] 300.00 [%] 300.00 [%]
p50183[0...n] Torque limiting torque limit 2 negative / T lim 2 neg
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 6825
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
-300.00 [%] 300.00 [%] -300.00 [%]