Description: Display and connector output of the setpoint/actual value difference after droop on the EMF controller.
Description: Display and connector output for the absolute value of the actual value on the EMF controller.
Dependency: Refer to: p50616
Note: A value of 100% corresponds to p50078[0] * (3 * sqrt(2)) / Pi.
Description: Displays the absolute value of the EMF actual value averaged over the last 3 firing periods (r52287).
Dependency: Refer to: r52287
Note: 100% corresponds to p50078[0] * (3 * sqrt(2)) / Pi
Description: Displays the signed EMF actual value averaged over the last 3 firing periods.
Note: 100% corresponds to p50078[0] * (3 * sqrt(2)) / Pi
Description: Display and connector output for the absolute value of the setpoint on the EMF controller.
Dependency: Refer to: p50615
Note: A value of 100% corresponds to p50078[0] * (3 * sqrt(2)) / Pi.
r52284 CO: EMF controller setpoint/actual value difference after droop / EMF ctr dif droop
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6900
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52285 CO: EMF controller actual value / EMF ctr act
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6900
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52286 CO: Average absolute value of EMF actual value / EMF act abs avg
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6902
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52287 CO: Average EMF actual value / EMF act avg
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6810, 6902,
8046
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52288 CO: EMF controller setpoint / EMF ctr set
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6900
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]