2 Parameters
2.2 List of parameters
SINAMICS DCM
518 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Sets the type for the digital inputs/outputs on the CUD.
Value: 0: Input
1: Output
Index: [0] = DI/DO 4 (X177.15)
[1] = DI/DO 5 (X177.16)
[2] = DI/DO 6 (X177.17)
[3] = DI/DO 7 (X177.18)
Note: DI/DO: Bidirectional Digital Input/Output
Description: Sets the operating mode for the peer-to-peer interface (P2P IF).
Value: 0: No function
5: Peer-to-peer communication
6: Communication with SIMOREG CCP
Note: P2P IF: Peer-to-peer interface
CCP: Converter Commutation Protector
Description: Sets the number of words to be transmitted for the peer-to-peer interface (P2P IF) in "Peer-to-peer communication"
mode (p50790 = 5).
Dependency: Refer to: p50790
Description: Sets the baud rate for the peer-to-peer interface (P2P IF).
Value: 1: 300 baud
2: 600 baud
3: 1200 baud
4: 2400 baud
5: 4800 baud
p50789[0...3] CUD digital inputs/outputs type / CUD DI/DO typ
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Integer16 Dyn. index: - Func. diagram: 2060, 2065
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1 0
p50790 P2P IF operating mode / P2P op mode
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Integer16 Dyn. index: - Func. diagram: 9300
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 6 0
p50791 P2P IF number of data words / P2P num words
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned16 Dyn. index: - Func. diagram: 9300
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
1 5 5
p50793 P2P IF baud rate / P2P baud rate
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Integer16 Dyn. index: - Func. diagram: 9300
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
1 13 13