EasyManua.ls Logo

Siemens SINAMICS DCM - EMF Setpoint Reduction Evaluation Factor; EMF Set Eval_Fact; EMF Setpoint Reduction Line Voltage Lower Limit; EMF Setpoint Reduction Line Voltage Smoothing Time; EMF Setpoint Reduction Line Voltage Upper Limit

Siemens SINAMICS DCM
1204 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
435
2 Parameters
2.2 List of parameters
Description: Sets the smoothing time for the line voltage for the EMF setpoint reduction.
Dependency: Refer to: p50286, p50287, p50288, p50289, r52294
Description: Sets the upper limit for the line voltage for EMF setpoint reduction.
Dependency: Refer to: p50287, p50288, p50289, r52294
Description: Sets the lower limit for the line voltage for the EMF setpoint reduction.
Dependency: Refer to: p50286, p50288, p50289, r52294
Description: Sets the evaluation factor for the EMF setpoint reduction.
Dependency: Refer to: p50286, p50287, p50289, r52294
Description: Sets the signal source to activate the EMF setpoint reduction.
Dependency: Refer to: p50285, p50286, p50287, p50288, r52294
p50285[0...n] EMF setpoint reduction line voltage smoothing time / EMF set line t_sm
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 6895
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.00 [s] 10.00 [s] 0.00 [s]
p50286[0...n] EMF setpoint reduction line voltage upper limit / EMF set line upper
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 6895
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
100.0 [%] 150.0 [%] 110.0 [%]
p50287[0...n] EMF setpoint reduction line voltage lower limit / EMF set line lower
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 6895
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
0.0 [%] 100.0 [%] 0.0 [%]
p50288[0...n] EMF setpoint reduction evaluation factor / EMF set eval_fact
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 6895
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
0.0 [%] 200.0 [%] 100.0 [%]
p50289[0...n] BI: EMF setpoint reduction activation signal source / EMF set act sig s
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dyn. index: CDS, p0170 Func. diagram: 6895
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0

Table of Contents

Other manuals for Siemens SINAMICS DCM

Related product manuals