2 Parameters
2.2 List of parameters
Description: Sets the IP address for the Communication Board Ethernet 20/25 (CBE20/CBE25).
Dependency: Refer to: p8940, p8942, p8943, p8944, p8945
Note: The interface configuration (p8940 and following) is activated with p8945.
The parameter is not influenced by setting the factory setting.
Description: Sets the standard gateway for the Communication Board Ethernet 20/25 (CBE20/CBE25).
Dependency: Refer to: p8940, p8941, p8943, p8944, p8945
Note: The interface configuration (p8940 and following) is activated with p8945.
The parameter is not influenced by setting the factory setting.
Description: Sets the subnet mask for the Communication Board Ethernet 20/25 (CBE20/CBE25).
Dependency: Refer to: p8940, p8941, p8942, p8944, p8945
Note: The interface configuration (p8940 and following) is activated with p8945.
The parameter is not influenced by setting the factory setting.
Description: Sets the DHCP mode for the Communication Board Ethernet 20/25 (CBE20/CBE25).
Dependency: Refer to: p8940, p8941, p8942, p8943, p8945
Notice: When the DHCP mode is active (p8944 > 0), then PROFINET communication via this interface is no longer possible!
However, the interface can be used by the STARTER/SCOUT commissioning tool.
Note: The active DHCP mode is displayed in parameter r8954.
The interface configuration (p8940 and following) is activated with p8945.
The parameter is not influenced by setting the factory setting.
p8941[0...3] CBE2x IP Address of Station / CBE2x IP of Stat
CU_DC (PROFINET
CBE20), CU_DC_R
(PROFINET CBE20),
CU_DC_R_S
(PROFINET CBE20),
CU_DC_S
(PROFINET CBE20)
Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned8 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 255 0
p8942[0...3] CBE2x Default Gateway of Station / CBE2x Def Gateway
CU_DC (PROFINET
CBE20), CU_DC_R
(PROFINET CBE20),
CU_DC_R_S
(PROFINET CBE20),
CU_DC_S
(PROFINET CBE20)
Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned8 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 255 0
p8943[0...3] CBE2x Subnet Mask of Station / CBE2x Subnet Mask
CU_DC (PROFINET
CBE20), CU_DC_R
(PROFINET CBE20),
CU_DC_R_S
(PROFINET CBE20),
CU_DC_S
(PROFINET CBE20)
Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned8 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 255 0
p8944 CBE2x DHCP Mode / CBE2x DHCP Mode
CU_DC (PROFINET
CBE20), CU_DC_R
(PROFINET CBE20),
CU_DC_R_S
(PROFINET CBE20),
CU_DC_S
(PROFINET CBE20)
Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned8 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 255 0