SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
519
2 Parameters
2.2 List of parameters
6: 9600 baud
7: 19200 baud
8: 38400 baud
9: 56700 baud
11: 93750 baud
13: 187500 baud
Description: Sets the signal source for the data to be transmitted on the peer-to-peer interface (P2P IF).
The transmit data is displayed in r50813[0 to 4].
Index: [0] = Word 1
[1] = Word 2
[2] = Word 3
[3] = Word 4
[4] = Word 5
Dependency: Refer to: r50813
Description: Sets the bus terminator for the peer-to-peer interface and the interface to the SIMOREG CCP.
Value: 0: OFF
1: ON
Note: CCP: Converter Commutation Protector
P2P: Peer-to-Peer interface
Description: Sets the telegram monitoring time for the peer-to-peer interface (P2P IF).
The time set is only effective in "Peer-to-peer interface" operating mode (p50790 = 5).
p50797 = 0:
Monitoring is de-activated.
p50797 > 0:
Monitoring is activated.
As well as one valid telegram being received, the next valid telegram must be received within the set time. Otherwise,
fault F60012 is triggered.
Dependency: Refer to: F60012
p50794[0...4] CI: P2P IF transmit data signal source / P2P tr data sig s
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned32 / Integer16 Dyn. index: - Func. diagram: 9300
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: 4000H Expert list: 1
Min Max Factory setting
- - 0
p50795 P2P/CCP bus terminator / P2P/CCP bus term
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Integer16 Dyn. index: - Func. diagram: 6970, 9300
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1 0
p50797 P2P IF telegram monitoring time / P2P t_telegr mon
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 9300
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.000 [s] 65.000 [s] 0.000 [s]