2 Parameters
2.2 List of parameters
SINAMICS DCM
30 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Operating display for Terminal Module 150 (TM150)
Value: 0: Module in cyclic operation
40: Module not in cyclic operation
50: Alarm
60: Fault
70: Initialization
120: Module de-activated
200: Wait for booting/partial booting
250: Device signals a topology error
Notice: For several missing enable signals, the corresponding value with the highest number is displayed.
Description: Operating display for Terminal Module 15 (TM15).
Value: 0: Module in cyclic operation
40: Module not in cyclic operation
50: Alarm
60: Fault
70: Initialization
120: Module de-activated
200: Wait for booting/partial booting
250: Device signals a topology error
Notice: For several missing enable signals, the corresponding value with the highest number is displayed.
Description: Operating display for Terminal Module 31 (TM31).
Value: 0: Module in cyclic operation
40: Module not in cyclic operation
50: Alarm
60: Fault
70: Initialization
120: Module de-activated
200: Wait for booting/partial booting
250: Device signals a topology error
Notice: For several missing enable signals, the corresponding value with the highest number is displayed.
r0002 TM150 operating display / TM150 op_display
TM150 Can be changed: - Calculated: - Access level: 1
Data type: Integer16 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 250 -
r0002 TM15DI/DO operating display / TM15D op_display
TM15DI_DO Can be changed: - Calculated: - Access level: 1
Data type: Integer16 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 250 -
r0002 TM31 operating display / TM31 op_display
TM31 Can be changed: - Calculated: - Access level: 1
Data type: Integer16 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 250 -