EasyManua.ls Logo

Siemens SINAMICS DCM - TM150 Operating Display; TM150 Op_Display; TM15 DI;DO Operating Display; TM15 D Op_Display; TM31 Operating Display; TM31 Op_Display

Siemens SINAMICS DCM
1204 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 Parameters
2.2 List of parameters
SINAMICS DCM
30 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Operating display for Terminal Module 150 (TM150)
Value: 0: Module in cyclic operation
40: Module not in cyclic operation
50: Alarm
60: Fault
70: Initialization
120: Module de-activated
200: Wait for booting/partial booting
250: Device signals a topology error
Notice: For several missing enable signals, the corresponding value with the highest number is displayed.
Description: Operating display for Terminal Module 15 (TM15).
Value: 0: Module in cyclic operation
40: Module not in cyclic operation
50: Alarm
60: Fault
70: Initialization
120: Module de-activated
200: Wait for booting/partial booting
250: Device signals a topology error
Notice: For several missing enable signals, the corresponding value with the highest number is displayed.
Description: Operating display for Terminal Module 31 (TM31).
Value: 0: Module in cyclic operation
40: Module not in cyclic operation
50: Alarm
60: Fault
70: Initialization
120: Module de-activated
200: Wait for booting/partial booting
250: Device signals a topology error
Notice: For several missing enable signals, the corresponding value with the highest number is displayed.
r0002 TM150 operating display / TM150 op_display
TM150 Can be changed: - Calculated: - Access level: 1
Data type: Integer16 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 250 -
r0002 TM15DI/DO operating display / TM15D op_display
TM15DI_DO Can be changed: - Calculated: - Access level: 1
Data type: Integer16 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 250 -
r0002 TM31 operating display / TM31 op_display
TM31 Can be changed: - Calculated: - Access level: 1
Data type: Integer16 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 250 -

Table of Contents

Other manuals for Siemens SINAMICS DCM

Related product manuals