SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
385
2 Parameters
2.2 List of parameters
Description: Displays the status during the optimization run.
Value: 0: No optimization run
1: Wait for operating state 7.4
2: Check prerequisites
3: Save original interconnection
4: Interconnect optimization parameters
5: Wait for operating state 0.x or 1.5
6: Set optimized parameter values
7: Wait for operating state 8.0
8: Troubleshooting
9: Exit optimization run
101: Set field current to 100%
102: Measure field circuit resistance
103: Measure field circuit inductance
201: Wait for field decay
202: Set armature current to 100%
203: Measure armature circuit resistance
204: Measure armature circuit inductance
301: Record speed characteristic
302: Stop motor
401: Calculate nominal EMF
402: Calculate nominal speed
403: Record field characteristic 91 % field current
404: Record field characteristic 83 % field current
405: Record field characteristic 76 % field current
406: Record field characteristic 70 % field current
407: Record field characteristic 65 % field current
408: Record field characteristic 60.5 % field current
409: Record field characteristic 56.5 % field current
410: Record field characteristic 53 % field current
411: Record field characteristic 50 % field current
412: Record field characteristic 47 % field current
413: Record field characteristic 44 % field current
414: Record field characteristic 41 % field current
415: Record field characteristic 38 % field current
416: Record field characteristic 35 % field current
417: Record field characteristic 32 % field current
418: Record field characteristic 29 % field current
419: Record field characteristic 26 % field current
420: Record field characteristic 23 % field current
421: Record field characteristic 20 % field current
422: Record field characteristic 17 % field current
423: Record field characteristic 14 % field current
424: Record field characteristic 11 % field current
425: Record field characteristic 8% field current
426: Recording of field characteristic is complete
501: Wait for field to build up
502: Recording the friction characteristic - 10% rated speed
503: Recording the friction characteristic - 20% rated speed
504: Recording the friction characteristic - 30% rated speed
505: Recording the friction characteristic - 40% rated speed
506: Recording the friction characteristic - 50% rated speed
507: Recording the friction characteristic - 60% rated speed
508: Recording the friction characteristic - 70% rated speed
509: Recording the friction characteristic - 80% rated speed
r50052 Optimization run status / Opt run status
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: Integer16 Dyn. index: - Func. diagram: 2660
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 701 -

Table of Contents

Other manuals for Siemens SINAMICS DCM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS DCM and is the answer not in the manual?

Siemens SINAMICS DCM Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS DCM
CategoryMedia Converter
LanguageEnglish

Related product manuals