2 Parameters
2.2 List of parameters
SINAMICS DCM
526 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Displays the communication error for armature and field voltage sensing.
Index: [0] = Number of CRC errors armature
[1] = Number of communication errors armature
[2] = Number of CRC errors field
[3] = Number of communication errors field
Description: Setting to reset the thyristor load data for a thyristor.
Value: 0: Do not reset data
1: Reset data
Index: [0] = Thyristor X11
[1] = Thyristor X12
[2] = Thyristor X13
[3] = Thyristor X14
[4] = Thyristor X15
[5] = Thyristor X16
[6] = Thyristor X21
[7] = Thyristor X22
[8] = Thyristor X23
[9] = Thyristor X24
[10] = Thyristor X25
[11] = Thyristor X26
Note: It is only permissible to reset the thyristor load data after a thyristor has been replaced.
Description: Sets message numbers for the diagnostics memory.
A trace is saved in the diagnostics file if one of these messages occurs.
Description: Displays the serial number of the gating module.
r50836[0...3] Voltage sensing communication error counter / V_sens comm_err
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: Unsigned32 Dyn. index: - Func. diagram: 8054
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
p50837[0...11] Reset thyristor load data / Thyr_load reset
DC_CTRL Can be changed: U, T Calculated: - Access level: 4
Data type: Integer16 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1 0
p50838[0...2] Diagnostics memory message number / Diag_mem msg_no
DC_CTRL Can be changed: U, T Calculated: - Access level: 1
Data type: Unsigned16 Dyn. index: - Func. diagram: 8052
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
60000 60999 60000
r50840[0...31] Gating module serial number / Gate_mod ser_no.
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: Unsigned8 Dyn. index: - Func. diagram: 6960
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -