SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
569
2 Parameters
2.2 List of parameters
Description: Display and connector output of the signed armature current actual value.
The value is averaged over 1 firing cycle.
Description: Display and connector output for the absolute value of the current controller actual value for closed-loop armature
current control.
Description: Display and connector output for the absolute value of the internal armature current actual value.
The value is averaged over one firing cycle.
Description: Display and connector output for the signed internal armature current actual value.
The value is averaged between the centers of the firing intervals.
Description: Display and connector output for the absolute value of the current controller setpoint for closed-loop armature current
control.
Dependency: Refer to: r50020
r52114 CO: Armature current actual value averaged over 1 cycle / Ia act 1 cyc
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6851
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52115 CO: Cl-loop arm curr control curr controller actual value abs value / Ia ctr I_act abs
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6855
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52116 CO: Armature current actual value internal absolute value / A I_act int abs
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6851
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52117 CO: Armature current actual value internal signed / A I_act int sign
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6851
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52118 CO: Cl-loop arm curr control curr controller setpoint absolute value / Ia ctr I_set abs
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6855
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]