SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
489
2 Parameters
2.2 List of parameters
Dependency: Refer to: p50621, p50622, p50624, r52165
Note: The setpoint/actual value difference (r52165) results from setpoint 1 and 2 (p50621, p50622) and actual value 1 and
2 (p50623, p50624).
Description: Sets the signal source for actual value 2 on the speed controller.
Dependency: Refer to: p50621, p50622, p50623, r52165
Note: The setpoint/actual value difference (r52165) results from setpoint 1 and 2 (p50621, p50622) and actual value 1 and
2 (p50623, p50624).
Description: Sets the signal source for the setpoint on the speed controller.
This signal can be smoothed using p50228.
Dependency: Refer to: p50228
Description: Sets the signal source to enable smoothing of the actual value on the speed controller.
Description: Sets the signal source for the derivative-action element.
Dependency: Refer to: p50205, p50206, r52168, r52169
p50624 CI: Signal source for speed controller actual value 2 / n_ctr act 2 sig s
DC_CTRL Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dyn. index: - Func. diagram: 6810
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 0
p50625[0...n] CI: Signal source for speed controller setpoint / n_ctr set sig s
DC_CTRL Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dyn. index: CDS, p0170 Func. diagram: 6810
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 52170[0]
p50626[0...n] CI: Signal source for speed controller actual value smoothing / Act v smoo sig s
DC_CTRL Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dyn. index: CDS, p0170 Func. diagram: 6810
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 52167[0]
p50627 CI: Derivative-action element signal source / D elem sig s
DC_CTRL Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dyn. index: - Func. diagram: 6810
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 52178[0]