SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
253
2 Parameters
2.2 List of parameters
Description: Display of the effective filter bandwidth for Sensor Module SMx10 (resolver) and SMx20 (sin/cos).
The bandwidth of the filter is set using p4660.
Index: [0] = Encoder 1
[1] = Encoder 2
[2] = Reserved
Dependency: Refer to: p4660
Note: A value of zero is displayed if an encoder is not present.
Description: Sets the ratio for the LVDT sensor.
Description: Sets the phase for the LVDT sensor.
Description: Sets the permissible tolerance in encoder pulses for the zero mark distance in the context of zero mark monitoring.
Causes fault F3x100 to appear less frequently.
Description: Sets the positive tolerance window in encoder pulses for limit 1 for the zero mark monitoring.
r4661[0...2] Sensor Module filter bandwidth display / SM Filt_bandw disp
DC_CTRL,
DC_CTRL_R,
DC_CTRL_R_S,
DC_CTRL_S
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Encoder Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [kHz] - [kHz] - [kHz]
p4678[0...n] Analog sensor LVDT ratio / An_sens LVDT ratio
DC_CTRL,
DC_CTRL_R,
DC_CTRL_R_S,
DC_CTRL_S
Can be changed: C2(4) Calculated: - Access level: 4
Data type: FloatingPoint32 Dyn. index: EDS, p0140 Func. diagram: -
P-Group: Encoder Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.00 [%] 200.00 [%] 50.00 [%]
p4679[0...n] Analog sensor LVDT phase / An_sens LVDT ph
DC_CTRL,
DC_CTRL_R,
DC_CTRL_R_S,
DC_CTRL_S
Can be changed: C2(4), T Calculated: - Access level: 4
Data type: FloatingPoint32 Dyn. index: EDS, p0140 Func. diagram: -
P-Group: Encoder Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
-360.00 [°] 360.00 [°] 0.00 [°]
p4680[0...n] Zero mark monitoring tolerance permissible / ZM_monit tol perm
DC_CTRL,
DC_CTRL_R,
DC_CTRL_R_S,
DC_CTRL_S
Can be changed: C2(4) Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: EDS, p0140 Func. diagram: -
P-Group: Encoder Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1000 4
p4681[0...n] Zero mark monitoring tolerance window limit 1 positive / ZM tol lim 1 pos
DC_CTRL,
DC_CTRL_R,
DC_CTRL_R_S,
DC_CTRL_S
Can be changed: C2(4) Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: EDS, p0140 Func. diagram: -
P-Group: Encoder Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1000 2