2 Parameters
2.2 List of parameters
SINAMICS DCM
644 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Displays the state of telegram monitoring on the peer-to-peer interface (P2P IF).
Note: The "Telegram monitoring timeout" signal is triggered:
- With binector output r53300.0 as a continuous signal
- With binector output r53300.1 as a one-off pulse with a duration of 1 s
Description: Displays the state of telegram monitoring on the parallel interface.
Dependency: Refer to: p50099, p51807
Refer to: F60014
Description: Displays the state of the parallel interface.
Dependency: Refer to: p51800
Description: Display and BICO output to control the contactors to switch over the power unit topology.
r53300.0...1 CO/BO: P2P IF telegram monitoring state / P2P telegr mon
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: Unsigned16 Dyn. index: - Func. diagram: 9300
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Telegram monitoring timeout Yes No 9300
01 Telegram monitoring timeout and 1 s pulse
pending
Yes No 9300
r53310.0...1 CO/BO: Parallel interface telegram monitoring state / Par IF mon state
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: Unsigned16 Dyn. index: - Func. diagram: 9350
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Telegram monitoring timeout - continuous
signal
Yes No 9350
01 Telegram monitoring timeout - pulse Yes No 9350
r53311.0 CO/BO: Parallel interface master/slave state / Par IF ma/sl state
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: Unsigned16 Dyn. index: - Func. diagram: 9350
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Active master Master Slave 9350
r53312.0...1 CO/BO: Topology switchover command / Top_sw command
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: Unsigned16 Dyn. index: - Func. diagram: 9360
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -