2 Parameters
2.2 List of parameters
SINAMICS DCM
464 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Sets how the output value is saved on the motorized potentiometer.
Value: 0: Save de-activated
1: Save activated
Dependency: Refer to: p50467, r52240
Note: If p50473 = 0:
The output value (CI: r52240) is not saved. The starting value specified in p50467 is applied after ON.
If p50473 = 1:
The output value (CI: r52240) is saved to non-volatile memory after OFF. The saved value is applied after ON.
Description: Sets setpoint 1 for the square-wave generator.
Dependency: Refer to: p50481, p50482, p50483
Note: This setpoint is applied for the time set in p50481.
Description: Sets the time during which setpoint 1 should be applied for the square-wave generator.
Dependency: Refer to: p50480, p50482, p50483
Description: Sets setpoint 2 for the square-wave generator.
Dependency: Refer to: p50480, p50481, p50483
Note: This setpoint is applied for the time set in p50483.
p50473[0...n] Motorized potentiometer save output value / MotP save outp val
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Integer16 Dyn. index: DDS, p0180 Func. diagram: 3110
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1 0
p50480[0...n] Oscillation setpoint 1 / Oscillation set 1
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 3120
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
-200.0 [%] 200.0 [%] 0.5 [%]
p50481[0...n] Oscillation setpoint 1 time / Oscill set 1 t
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 3120
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.1 [s] 300.0 [s] 0.1 [s]
p50482[0...n] Oscillation setpoint 2 / Oscillation set 2
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 3120
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
-200.0 [%] 200.0 [%] -0.4 [%]