2 Parameters
2.2 List of parameters
SINAMICS DCM
508 List Manual (LH8), 02/2015, 6RX1800-0ED76
Index: [0] = Select input 3 (X177.1/2)
[1] = Select input 4 (X177.3/4)
[2] = Select input 5 (X177.5/6)
[3] = Select input 6 (X177.7/8)
Description: Sets the signal source for enabling fast analog inputs "Select input 3 to 6".
Index: [0] = Select input 3 (X177.1/2)
[1] = Select input 4 (X177.3/4)
[2] = Select input 5 (X177.5/6)
[3] = Select input 6 (X177.7/8)
Note: 1 signal:
Analog input is enabled
0 signal:
Analog input is disabled (value = 0%)
Description: Sets the setpoint for the simulation of the fast analog inputs (select input 3 ... 6).
Index: [0] = Select input 3 (X177.1/2)
[1] = Select input 4 (X177.3/4)
[2] = Select input 5 (X177.5/6)
[3] = Select input 6 (X177.7/8)
Dependency: Refer to: p50739
Note: Simulation is selected using p50739[0...3] = 1.
Description: Setting to select the simulation of the fast analog inputs (select input 3 ... 6).
Value: 0: Simulation deactivated
1: Simulation activated
Index: [0] = Select input 3 (X177.1/2)
[1] = Select input 4 (X177.3/4)
[2] = Select input 5 (X177.5/6)
[3] = Select input 6 (X177.7/8)
Dependency: Refer to: p50737
Note: The setpoint for the simulation is set in p50737[0...3].
p50736[0...3] BI: Signal source to enable fast analog inputs / Fast AI ena sig s
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dyn. index: - Func. diagram: 2085, 2090
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 1
p50737[0...3] Fast analog inputs setpoint simulation / Fast AI sim setp
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 2085, 2090
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
-130.0 [%] 130.0 [%] 0.0 [%]
p50739[0...3] Fast analog inputs simulation selection / Fast AI sim sel
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Integer16 Dyn. index: - Func. diagram: 2085, 2090
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1 0