2 Parameters
2.2 List of parameters
SINAMICS DCM
580 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Display and connector output for output value of band-stop 2.
Dependency: Refer to: p50203, p50204, p50629
Description: Display and connector output of the smoothed actual value on the speed controller.
Description: Display and connector output for the effective positive setpoint limit with "Limiting after ramp-function generator".
Description: Display and connector output for the effective negative setpoint limit with "Limiting after ramp-function generator".
Description: Display and connector output for the speed setpoint with "Limiting after ramp-function generator".
r52178 CO: Band-stop 2 output value / Band-st 2 outp
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6810
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52179 CO: Speed controller actual value smoothed / n_ctr act sm
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6810
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52181 CO: RFG effective positive setpoint limit / RFG set lim pos
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 3155
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52182 CO: RFG effective negative setpoint limit / RFG set lim neg
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 3155
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52183 CO: RFG speed setpoint before limiting / RFG n_set bef lim
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 3155
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]