2 Parameters
2.2 List of parameters
SINAMICS DCM
462 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Sets the expansion factor on the motorized potentiometer.
Value: 0: Factor 1
1: Factor 60
Dependency: Refer to: p50462, p50463, p50464
Note: The expansion factor affects the following parameters:
- p50462 (ramp-up time)
- p50463 (ramp-down time)
- p50464 (time difference for dy/dt)
Description: Sets the signal source for the setting value for the motorized potentiometer.
Dependency: Refer to: p50472
Note: The setting value (CI: p50466) becomes effective on a 0/1 edge of the setting command (BI: p50472).
Description: Sets the starting value on the motorized potentiometer.
Dependency: Refer to: p50473
Note: The value is only effective when saving of the output value is de-activated (p50473 = 0).
Description: Sets the maximum speed on the motorized potentiometer.
Dependency: Refer to: p50471
Note: This parameter is only effective in manual mode (p50471 = 0).
The setpoint output from the motorized potentiometer is limited to this value.
p50465[0...n] Motorized potentiometer expansion factor / MotP exp fact
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: Integer16 Dyn. index: DDS, p0180 Func. diagram: 3110
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1 0
p50466[0...n] CI: Motor potentiometer setting value signal source / MotP s val sig s
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / FloatingPoint32 Dyn. index: CDS, p0170 Func. diagram: 3110
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 0
p50467[0...n] Motorized potentiometer starting value / MotP start value
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 3110
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
-200.00 [%] 200.00 [%] 0.00 [%]
p50468[0...n] Motorized potentiometer maximum speed / MotP n_max
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 3110
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
-200.00 [%] 200.00 [%] 100.00 [%]