EasyManuals Logo

Siemens SINAMICS DCM List Manual

Siemens SINAMICS DCM
1204 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #462 background imageLoading...
Page #462 background image
2 Parameters
2.2 List of parameters
SINAMICS DCM
462 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Sets the expansion factor on the motorized potentiometer.
Value: 0: Factor 1
1: Factor 60
Dependency: Refer to: p50462, p50463, p50464
Note: The expansion factor affects the following parameters:
- p50462 (ramp-up time)
- p50463 (ramp-down time)
- p50464 (time difference for dy/dt)
Description: Sets the signal source for the setting value for the motorized potentiometer.
Dependency: Refer to: p50472
Note: The setting value (CI: p50466) becomes effective on a 0/1 edge of the setting command (BI: p50472).
Description: Sets the starting value on the motorized potentiometer.
Dependency: Refer to: p50473
Note: The value is only effective when saving of the output value is de-activated (p50473 = 0).
Description: Sets the maximum speed on the motorized potentiometer.
Dependency: Refer to: p50471
Note: This parameter is only effective in manual mode (p50471 = 0).
The setpoint output from the motorized potentiometer is limited to this value.
p50465[0...n] Motorized potentiometer expansion factor / MotP exp fact
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: Integer16 Dyn. index: DDS, p0180 Func. diagram: 3110
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1 0
p50466[0...n] CI: Motor potentiometer setting value signal source / MotP s val sig s
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / FloatingPoint32 Dyn. index: CDS, p0170 Func. diagram: 3110
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 0
p50467[0...n] Motorized potentiometer starting value / MotP start value
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 3110
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
-200.00 [%] 200.00 [%] 0.00 [%]
p50468[0...n] Motorized potentiometer maximum speed / MotP n_max
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 3110
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
-200.00 [%] 200.00 [%] 100.00 [%]

Table of Contents

Other manuals for Siemens SINAMICS DCM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS DCM and is the answer not in the manual?

Siemens SINAMICS DCM Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS DCM
CategoryMedia Converter
LanguageEnglish

Related product manuals