2 Parameters
2.2 List of parameters
Description: Display and connector output for the output value of the proportional component on the speed controller.
Description: Display and connector output for the integral component of the speed controller's output value.
Description: Display and connector output of the speed setpoint/actual value difference used for the speed controller.
Dependency: Refer to: p50620
Description: Display and connector output for the result of the setpoint/actual value difference on the speed controller.
Dependency: Refer to: p50621, p50622, p50623, p50624
Note: The setpoint/actual value difference (r52165) results from setpoint 1 and 2 (p50621, p50622) and actual value 1 and
2 (p50623, p50624).
Description: Display and connector output of the selected speed actual value as an absolute value on the speed controller.
r52161 CO: Speed controller proportional component output value / P comp outp val
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6815
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52162 CO: Speed controller integral component output value / I_comp outp val
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6815
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52164 CO: Speed controller setpoint/actual value difference / n_ctr set/act dif
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6815, 6820
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52165 CO: Speed controller setpoint/actual value difference / n_ctr set/act dif
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6810
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52166 CO: Speed controller actual value selection absolute value / Sel act abs
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6810, 6815,
6825, 6900, 8040, 8046
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]