2 Parameters
2.2 List of parameters
SINAMICS DCM
460 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Sets the signal sources for generating the creep setpoint (CO: r52201).
Dependency: Refer to: r52201
Description: Setting to enable/disable the impact of the individual creep setpoints when generating signal r53170.12, "Bypass
ramp-function generator".
Value: 0: Do not bypass
1: Bypass
Note: [0]: Enable bypassing of ramp-function generator at creep setpoint 0
...
[7]: Enable bypassing of ramp-function generator at creep setpoint 7
Description: Sets the signal source for the default setpoint when creep is not selected.
Description: Sets the signal source for shutting down/resetting the injection of the creep setpoint.
Description: Sets whether the ON command is triggered by a logic 1 level or a 0/1 edge.
p50441[0...7] CI: Signal source for creep setpoint / Cr set sig s
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / FloatingPoint32 Dyn. index: - Func. diagram: 3130
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 0
p50442[0...7] Creep setpoint bypass ramp-function generator / Cr set bypass RFG
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Integer16 Dyn. index: - Func. diagram: 3130
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1 0
p50443[0...n] CI: Creep signal source for default setpoint / Cr def set sig s
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / FloatingPoint32 Dyn. index: CDS, p0170 Func. diagram: 3130
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 52207[0]
p50444[0...n] BI: Creep signal source for shutdown / Cr shutdn sig s
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dyn. index: CDS, p0170 Func. diagram: 3130
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0
p50445 Creep setpoint level/edge / Cr set lev/ed
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Integer16 Dyn. index: - Func. diagram: 3130
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1 0

Table of Contents

Other manuals for Siemens SINAMICS DCM