2 Parameters
2.2 List of parameters
SINAMICS DCM
516 List Manual (LH8), 02/2015, 6RX1800-0ED76
Value: 0: Not inverted
1: Inverted
Index: [0] = DI/DO 4 (X177.15)
[1] = DI/DO 5 (X177.16)
[2] = DI/DO 6 (X177.17)
[3] = DI/DO 7 (X177.18)
Dependency: The terminal must be set as an output (p50789[0...3]).
Refer to: p50789
Note: DI/DO: Bidirectional Digital Input/Output
Description: Sets the signal source for digital input/output 4 (X177.15) on the CUD.
Dependency: The terminal must be set as an output (p50789[0] = 1).
Refer to: p50789
Description: Sets the signal source for digital input/output 5 (X177.16) on the CUD.
Dependency: The terminal must be set as an output (p50789[1] = 1).
Refer to: p50789
Description: Sets the signal source for digital input/output 6 (X177.17) on the CUD.
Dependency: The terminal must be set as an output (p50789[2] = 1).
Refer to: p50789
Description: Sets the signal source for digital input/output 7 (X177.18) on the CUD.
Dependency: The terminal must be set as an output (p50789[3] = 1).
Refer to: p50789
p50781 BI: CUD digital input/output 4 signal source / CUD DI/DO 4 sig s
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dyn. index: - Func. diagram: 2060
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0
p50782 BI: CUD digital input/output 5 signal source / CUD DI/DO 5 sig s
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dyn. index: - Func. diagram: 2060
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0
p50783 BI: CUD digital input/output 6 signal source / CUD DI/DO 6 sig s
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dyn. index: - Func. diagram: 2065
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0
p50784 BI: CUD digital input/output 7 signal source / CUD DI/DO 7 sig s
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dyn. index: - Func. diagram: 2065
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0