2 Parameters
2.2 List of parameters
SINAMICS DCM
590 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Display and connector output of the sum of the outputs from EMF pre-control and the EMF controller.
Description: Display and connector output on the EMF controller.
Description: Display and connector output of the proportional component on the EMF controller.
Description: Display and connector output of the integral component on the EMF controller.
Description: Display and connector output of the setpoint/actual value difference on the EMF controller.
r52278 CO: EMF controller pre-control and controller output / EMF prec+ctrl outp
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6900
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52280 CO: EMF controller output / EMF ctr outp
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6900
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52281 CO: EMF controller proportional component output / EMF ctr P com outp
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6900
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52282 CO: EMF controller integral component output / EMF ctr I com outp
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6900
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52283 CO: EMF controller setpoint/actual value difference / EMF ctr dif
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6900
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]