SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
627
2 Parameters
2.2 List of parameters
Description: Displays the DC offset (= direct-current component) of the field line phases in volts.
Description: Displays the point in time (timer value) of the last positive zero crossing of armature phase UV.
Note: The value is displayed in [10 ns] unit.
Description: Displays the point in time (timer value) of the last negative zero crossing of armature phase UV.
Note: The value is displayed in [10 ns] unit.
Description: Displays the point in time (timer value) of the last positive zero crossing of armature phase VW.
Note: The value is displayed in [10 ns] unit.
Description: Displays the point in time (timer value) of the last negative zero crossing of armature phase UV.
Note: The value is displayed in [10 ns] unit.
r52966 Line analysis field line phase offset / Field line ph offs
DC_CTRL Can be changed: - Calculated: - Access level: 4
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6952
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [V] - [V] - [V]
r52970 CO: Line analysis armature line zero crossing positive phase UV / Arm zero pos UV
DC_CTRL Can be changed: - Calculated: - Access level: 4
Data type: Unsigned32 Dyn. index: - Func. diagram: 6950
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r52971 CO: Line analysis armature line zero crossing negative phase UV / Arm zero neg UV
DC_CTRL Can be changed: - Calculated: - Access level: 4
Data type: Unsigned32 Dyn. index: - Func. diagram: 6950
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r52972 CO: Line analysis armature line zero crossing positive phase VW / Arm zero pos VW
DC_CTRL Can be changed: - Calculated: - Access level: 4
Data type: Unsigned32 Dyn. index: - Func. diagram: 6950
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r52973 CO: Line analysis armature line zero crossing negative phase VW / Arm zero neg VW
DC_CTRL Can be changed: - Calculated: - Access level: 4
Data type: Unsigned32 Dyn. index: - Func. diagram: 6950
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -