2 Parameters
2.2 List of parameters
SINAMICS DCM
260 List Manual (LH8), 02/2015, 6RX1800-0ED76
Index: [0] = Trace 0
[1] = Trace 1
Dependency: Only effective when p4710 = 6.
Description: Sets the trigger condition for bit mask trigger.
Index: [0] = Trace 0
[1] = Trace 1
Dependency: Only effective when p4710 = 6.
Description: Displays the trigger index in the trace buffer. The trigger event occurred at this point.
Index: [0] = Trace 0
[1] = Trace 1
Dependency: Only valid when p4705 = 4.
Description: Sets the recording cycle for the trace.
Index: [0] = Trace 0
[1] = Trace 1
Description: Sets the recording time for the trace.
Index: [0] = Trace 0
[1] = Trace 1
p4716[0...1] Trace bit mask trigger trigger condition / Trace Trig_cond
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Trace and function generator Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
0 4294967295 0
r4719[0...1] Trace trigger index / Trace Trig_index
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Trace and function generator Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
- - -
p4720[0...1] Trace recording cycle / Trace record_cyc
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: U, T Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Trace and function generator Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
0.000 [ms] 60000.000 [ms] 1.000 [ms]
p4721[0...1] Trace recording time / Trace record_time
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: U, T Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Trace and function generator Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
0.000 [ms] 3600000.000 [ms] 1000.000 [ms]

Table of Contents

Other manuals for Siemens SINAMICS DCM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS DCM and is the answer not in the manual?

Siemens SINAMICS DCM Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS DCM
CategoryMedia Converter
LanguageEnglish

Related product manuals