SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
93
2 Parameters
2.2 List of parameters
Re p0496 = 42: 2500 Ohm <--> 2^32
Re p0496 = 51: 1 rpm <--> 1000 dec
Re p0496 = 52: In 1/4 encoder pulses
Re p0496 = 60: voltage, channel A in mV, voltage, channel B in mV
Re p0496 = 61: Channel A: encoder periods <--> 2^16, channel B: encoder periods <--> 2^16
Re p0496 = 62: encoder periods <--> 2^16
Re p0496 = 70: r: 100% <--> 10000 dec, phase: 180 ° <--> 18000 dec
Re p0496 = 80, 81, 85, 86: 1V <--> 1000 inc
Description: Displays the trace signal for encoder diagnostics (double word).
The signal to be output is selected in p0496.
Index: [0] = Encoder 1
[1] = Encoder 2
[2] = -
Dependency: Refer to: p0496, r0498, r0499
Description: Displays the trace signal for encoder diagnostics (low component).
The signal to be output is selected in p0496.
Index: [0] = Encoder 1
[1] = Encoder 2
[2] = -
Dependency: Refer to: p0496, r0497, r0499
Description: Displays the trace signal for encoder diagnostics (high component).
The signal to be output is selected in p0496.
Index: [0] = Encoder 1
[1] = Encoder 2
[2] = -
Dependency: Refer to: p0496, r0497, r0498
r0497[0...2] CO: Encoder diagnostic signal double word / Enc diag DW
DC_CTRL,
DC_CTRL_R,
DC_CTRL_R_S,
DC_CTRL_S
Can be changed: - Calculated: - Access level: 4
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Encoder Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r0498[0...2] CO: Encoder diagnostic signal low word / Enc diag low word
DC_CTRL,
DC_CTRL_R,
DC_CTRL_R_S,
DC_CTRL_S
Can be changed: - Calculated: - Access level: 4
Data type: Integer16 Dyn. index: - Func. diagram: -
P-Group: Encoder Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r0499[0...2] CO: Encoder diagnostic signal high word / Enc diag high word
DC_CTRL,
DC_CTRL_R,
DC_CTRL_R_S,
DC_CTRL_S
Can be changed: - Calculated: - Access level: 4
Data type: Integer16 Dyn. index: - Func. diagram: -
P-Group: Encoder Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -

Table of Contents