EasyManuals Logo

Siemens SINAMICS DCM List Manual

Siemens SINAMICS DCM
1204 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #400 background imageLoading...
Page #400 background image
2 Parameters
2.2 List of parameters
SINAMICS DCM
400 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Sets armature current I1 according to the motor's nameplate for "speed-dependent current limitation".
The characteristic for "speed-dependent current limitation" is defined by 2 pairs of values (p50104/p50105,
p50106/p50107).
This parameter sets armature current I1 for the first pair of values (p50104/p50105).
Dependency: Refer to: p50104, p50106, p50107, p50108, p50109
Note: The following condition applies:
p50105 >= p50107 (I1 >= I2)
Description: Sets speed n2 according to the motor's nameplate for "speed-dependent current limitation".
The characteristic for "speed-dependent current limitation" is defined by 2 pairs of values (p50104/p50105,
p50106/p50107).
This parameter sets speed n2 for the second pair of values (p50106/p50107).
Dependency: Refer to: p50104, p50105, p50107, p50108, p50109
Note: The following condition applies:
p50104 <= p50106 (n1 <= n2)
Description: Sets armature current I2 according to the motor's nameplate for "speed-dependent current limitation".
The characteristic for "speed-dependent current limitation" is defined by 2 pairs of values (p50104/p50105,
p50106/p50107).
This parameter sets armature current I2 for the second pair of values (p50106/p50107).
Dependency: Refer to: p50104, p50105, p50106, p50108, p50109
Note: The following condition applies:
p50105 >= p50107 (I1 >= I2)
p50105[0...n] Speed-dependent current limitation armature current I1 / I_lim n_dep I1
DC_CTRL Can be changed: C2(1), U, T Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 8040
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.1 [A] 20000.0 [A] 0.1 [A]
p50106[0...n] Speed-dependent current limitation speed n2 / I_lim n_dep n2
DC_CTRL Can be changed: C2(1), U, T Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 8040
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
1 [1 rpm] 10000 [1 rpm] 5000 [1 rpm]
p50107[0...n] Speed-dependent current limitation armature current I2 / I_lim n_dep I2
DC_CTRL Can be changed: C2(1), U, T Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 8040
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.1 [A] 20000.0 [A] 0.1 [A]

Table of Contents

Other manuals for Siemens SINAMICS DCM