2 Parameters
2.2 List of parameters
SINAMICS DCM
400 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Sets armature current I1 according to the motor's nameplate for "speed-dependent current limitation".
The characteristic for "speed-dependent current limitation" is defined by 2 pairs of values (p50104/p50105,
p50106/p50107).
This parameter sets armature current I1 for the first pair of values (p50104/p50105).
Dependency: Refer to: p50104, p50106, p50107, p50108, p50109
Note: The following condition applies:
p50105 >= p50107 (I1 >= I2)
Description: Sets speed n2 according to the motor's nameplate for "speed-dependent current limitation".
The characteristic for "speed-dependent current limitation" is defined by 2 pairs of values (p50104/p50105,
p50106/p50107).
This parameter sets speed n2 for the second pair of values (p50106/p50107).
Dependency: Refer to: p50104, p50105, p50107, p50108, p50109
Note: The following condition applies:
p50104 <= p50106 (n1 <= n2)
Description: Sets armature current I2 according to the motor's nameplate for "speed-dependent current limitation".
The characteristic for "speed-dependent current limitation" is defined by 2 pairs of values (p50104/p50105,
p50106/p50107).
This parameter sets armature current I2 for the second pair of values (p50106/p50107).
Dependency: Refer to: p50104, p50105, p50106, p50108, p50109
Note: The following condition applies:
p50105 >= p50107 (I1 >= I2)
p50105[0...n] Speed-dependent current limitation armature current I1 / I_lim n_dep I1
DC_CTRL Can be changed: C2(1), U, T Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 8040
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.1 [A] 20000.0 [A] 0.1 [A]
p50106[0...n] Speed-dependent current limitation speed n2 / I_lim n_dep n2
DC_CTRL Can be changed: C2(1), U, T Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 8040
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
1 [1 rpm] 10000 [1 rpm] 5000 [1 rpm]
p50107[0...n] Speed-dependent current limitation armature current I2 / I_lim n_dep I2
DC_CTRL Can be changed: C2(1), U, T Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 8040
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.1 [A] 20000.0 [A] 0.1 [A]