2 Parameters
2.2 List of parameters
Description: Sets the setpoint for the positive start pulse on the speed controller.
Recommendation: The value can also be used as an integrator setting value for the speed controller.
Description: Sets the factor for the start pulse when the setpoint is negative.
Description: Sets the setpoint for the negative start pulse on the speed controller.
Description: Sets the signal source for the setpoint of the positive start pulse on the speed controller.
Description: Sets the signal source for the setpoint of the negative start pulse on the speed controller.
p51651[0...n] Speed controller start pulse positive setpoint / Start pul pos set
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 6800
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
-100.00 [%] 100.00 [%] 0.00 [%]
p51652[0...n] Speed controller start pulse negative factor / Start pul neg fact
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 6800
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
0.00 [%] 200.00 [%] 50.00 [%]
p51653[0...n] Speed controller start pulse negative setpoint / Start pul neg set
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 6800
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
-100.00 [%] 100.00 [%] 0.00 [%]
p51655 CI: Speed controller start pulse positive signal source / Start p pos sig s
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / FloatingPoint32 Dyn. index: - Func. diagram: 6800
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 52451[0]
p51656 CI: Speed controller start pulse negative signal source / Start p neg sig s
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / FloatingPoint32 Dyn. index: - Func. diagram: 6800
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 52452[0]